Choose Tool fixed ozone (O3) gas monitor to provide reliable ozone detection in your working environment, covering a range of 0 to 1/5/10/20/50/100 ppm, with flexible configuration options. The compact size of the unit makes ozone detector easy to carry and install, making it ideal for monitoring applications that require mobility. Supporting 4-20mA and RS485 signal outputs, optional relay outputs and a high brightness display ensure that you are always aware of changes in gas concentration. Buy now to take advantage of promotional offers.
Specification
| Model |
GD300-O3 |
| Detection Principle |
Electrochemistry |
| Gas |
Ozone (O3) |
| Range (Optional) |
0-1 ppm |
| 0-5 ppm |
| 0-10 ppm |
| 0-20 ppm |
| 0-50 ppm |
| 0-100 ppm |
| Resolution |
0.001ppm (0-1ppm), 0.01ppm (0-5/10/20/50ppm), or 0.1ppm (0-100ppm) |
| Calibration Kit |
Gas pressure regulator (calibration gas cylinder NOT included) |
| Accuracy |
≤±3% F.S. |
| Responce Time |
≤10s |
| Repeatability |
≤±1% |
| Recovery Time |
≤10s |
| Linearity Error |
≤±1% |
| Zero Shift |
≤±1% (F.S./year) |
| Signal Output (Optional) Note |
4-20mA and RS485 Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional). |
| Alarms |
Sound, light |
| Display |
High light nixie tube display |
| Installation |
Wall-mounted, piping type, flow-type (according to the detected environment) |
| Connection |
Power connection type: G1/2 male thread explosion-proof flexible pipe Pipe-mounted type: M45*P2.0 |
| Operating Time |
24h |
| Explosion-proof Grade |
II 2G Ex db IIC T4 Gb |
| Protection Grade |
IP65 |
| Certification |
CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014) |
| Working Voltage |
12~36V DC |
| Case Material |
Die-casting aluminum housing |
| Operating Temperature |
-20℃~50℃ |
| Operating Humidity |
0~95%RH (non-condensing) |
| Dimension |
206*179*90mm |
| Weight |
≤1.6kg |
| Power Adapter |
Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug) |
Fixed Gas Monitor User Manual
Gas Monitor Functions
- This hydrogen sulfide gas detector adopts three-wire 4-20mA analog signal output, relay output, RS485 output (optional).
- The original imported sensors, with a unique infrared remote control function, non-contact operation and maintenance of hydrogen gas tester.
- Compatible with a variety of control alarms, PLC, DCS and other control systems, you can realize remote monitoring, gas monitoring is more accurate and reliable.
- Explosion-proof design, fast, credible and more stable.
- Full software auto-calibration function with temperature compensation can perfectly realize the compensation of gas concentration under different temperature environment.
Fixed O3 Gas Monitor Details

Fixed Ozone Gas Monitor with Alarm Dimension (Unit: mm)

Tips: How do I choose the right ozone detection range?
When selecting a fixed ozone gas monitor, the appropriate detection range depends on the ozone concentration in your application scenario. Our ozone gas detector is available in 0-1 ppm, 0-5 ppm, 0-10 ppm, 0-20 ppm, 0-50 ppm, and 0-100 ppm. If you are using it for environmental monitoring or need to detect low concentrations of ozone, the 0-1 ppm range may be more appropriate. For industrial applications, especially in the vicinity of ozone generators, it is recommended to choose a detector with a higher range, such as 0-20 ppm or 0-100 ppm. choosing the right range not only provides accurate data, but also ensures the longevity and stability of the ozone detector.