A particle counter is a precision measuring instrument that detects, counts and sizes solid particles suspended in air or liquid media. Air particle counters capture airborne particulate matter to verify air cleanliness levels inside cleanrooms, labs and controlled environments. Liquid particle counters (like hydraulic oil particle counters) analyze contaminant particles within oil fluids to monitor fluid cleanliness and equipment wear.
Particle counters quantify particles at different micron sizes (μm), the standard unit for particle diameter. Cleanroom certification, routine air audits, indoor air quality testing and fluid contamination control all rely on particle counter readings to meet ISO cleanroom standards.
Most air particle counters use laser light scattering technology. As sampled air passes through a laser beam, airborne particles scatter light. Photodetectors capture these light pulses; the signal strength correlates to particle size, while pulse frequency calculates particle concentration count per volume of air.
The instrument pulls in air at a fixed sampling flow rate (common: 2.83L/min or 28.3L/min). It sorts particles into multiple size channels and displays real-time particle counts. Advanced models automatically classify cleanroom grades, log data, print reports or transmit data via WiFi/Bluetooth.
Wondering how to choose a Laser particle counter? Follow our step-by-step guide to select the right particle counter for cleanroom validation, IAQ testing and industrial monitoring, covering flow rate, sensors, calibration and data output.
1. Clarify Your Testing Objectives
Start by defining your core use case. Whether you are performing cleanroom qualification, industrial air hygiene sampling, indoor air quality audits or routine environmental monitoring, your goal will decide the measurement range, accuracy grade and essential functions your instrument must have.
2. Pick the Right Form Factor
Choose the hardware style to match your workflow. Handheld particle counters deliver portability for on-site spot checks; benchtop units offer higher stability for laboratory analysis; fixed inline monitoring systems are ideal for uninterrupted long-term continuous sampling in production environments.
3.Inspect Optical Sensor Performance
Most reliable particle counters adopt laser diode optical sensing technology. Always validate sensor performance data. Steer clear of generic unvalidated sensor assemblies that lack independent test reports and performance verification documents.
4. Confirm Sampling Flow Rate Requirements
Match the instrument flow rate to your compliance rules. 1 CFM flow models are widely required to meet ISO cleanroom standards. For quick screening and preliminary spot inspections, 0.1 CFM instruments can be an economical alternative.
5. Understand Calibration Requirements
Check if the instrument ships with an official calibration certificate. Confirm the recommended recalibration cycle, as regular calibration (usually yearly) guarantees consistent, traceable measurement results over time.
6. Examine Data Storage & Export Capabilities
Prioritize models with flexible data management. Look for built-in data logging and multiple export options including USB, SD card or wireless transmission. CSV format compatibility simplifies offline data sorting, reporting and further analysis.
7. Account for Maintenance & Future Scalability
Before purchasing, consider long-term servicing ease, spare part availability and technical support. Select versatile instruments that can adapt if your particle size testing range or monitoring needs expand in future projects.
Our lineup of particle counters covers diverse monitoring scenarios, from portable on-site spot checks to fixed long-term continuous environmental sampling, to match different cleanroom, industrial hygiene and indoor air quality measurement demands.
| SKU | Type | Sampling Flow | Key Features |
| T-DT-9851M | Handheld Air Particle Counter | 2.83L/min | 4-in-1: 0.3/2.5/10μm, PM2.5/PM10, HCHO, Temp & RH; Sunlight-readable TFT, data storage |
| T-LY-DUST600 | Handheld Air Particle Counter | 2.83L/min | 0.3~10μm particle measurement, high-precision laser sensor; -10~50℃, ≤90%RH non-condensing |
| T-HD-CL10S | Benchtop Air Particle Counter | 28.3L/min | 6 particle channels, cleanroom grade judgment, built-in printer, AC/DC rechargeable lithium battery |
| T-HT-9600 | Handheld Air Particle Counter | 2.83L/min | Detect 0.3μm,2.5μm,10μm; wide working range -10~50℃, 0~99%RH |
| T-LD-CL1 | Handheld Air Particle Counter | 2.83L/min | 3.5” touch LCD, optional Bluetooth printer, 6 channels, WiFi & Bluetooth data transmission |
| T-PC002EU | Benchtop Air Particle Counter | 2.83L/min | 6 detection channels, built-in thermal printer, 5-inch touchscreen, real-time cleanroom classification |
| T-YP-Y10 | Liquid / Oil Particle Counter | Liquid sampling | Measure impurity particles 1μm~500μm in hydraulic oil, rugged suitcase enclosure |
| T-CLJ-H630 | Handheld Air Particle Counter | 2.83L/min | 6 particle channels, up to 260,000 data records storage, lightweight handheld |
Handheld Particle Counter
Our portable handheld model features compact size and lightweight design for easy field mobility. Built-in laser optical sensor delivers stable particle counting across multiple size channels. It supports on-screen real-time data display, built-in data logging and flexible export via USB. Ideal for cleanroom spot validation, IAQ site surveys, on-site troubleshooting and short-period sampling. Suitable for users needing to move between multiple test locations.
Benchtop Particle Counter
Benchtop units are engineered for high-precision laboratory and stationary workshop testing. With higher sampling stability and expanded data storage capacity, this version supports detailed statistical reporting. It works well for formal cleanroom qualification tests, R&D particle analysis and repeated precision sampling tasks. It prioritizes measurement consistency and advanced reporting functions for lab professionals.
Fixed / Inline Continuous Particle Counter
The fixed monitoring model is designed for 24/7 unattended continuous monitoring in production clean zones. It features steady continuous sampling, remote data transmission and alarm triggers for particle concentration threshold breaches. Perfect for permanent cleanroom production lines where constant particle level tracking is required.
Core Differences Between Models
Q1: What flow rate particle counter do I need for cleanroom certification?
A: 28.3L/min laser particle counters are widely used for official cleanroom certification and ISO audits. 2.83L/min (0.1 CFM) handheld models are suitable for routine spot checks, daily monitoring and troubleshooting.
Q2: What particle sizes should I test in a cleanroom?
A: 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm and 10μm are the most common particle size channels for cleanroom classification. 0.3μm particles are the most numerous and critical for high-grade cleanrooms.
Q3: Can handheld particle counters measure temperature and humidity?
A: Some multi-function handheld particle counters (like SKU T-PC-DT-9851M) integrate temperature, relative humidity, PM2.5, PM10 and HCHO sensors. Basic particle counter models only count air particles.
Q4: Do your particle counters support data export or print reports?
A: Our product lineup includes models with built-in thermal printers, optional Bluetooth portable printers, WiFi & Bluetooth data transmission and large internal data storage to save logs for later export and audit records.