    Fixed Nitrogen (N2) Gas Tester, 0 to 100% VOL

    Buy a high quality nitrogen gas tester designed for nitrogen concentration detection and leakage monitoring. The gas monitor supports high precision measurement in the range of 0-100% VoL with an error of only 3% F.S. It can support remote control and provides a variety of output signal options of 4-20mA and RS485, which meets your different needs for using the gas detector in different environments.
    SKU: GD300-N2
    *
    *
    *
    *
    *
    $742.46
    i h
    Free shipping
    Delivery date: 6-12 days
    Overview

    Favorable price nitrogen gas tester for sale, measuring nitrogen content from 0 to 100% VoL, equipped with 4-20mA and RS485 signal output, using wall-mounted, pipeline and other installation methods. N2 gas detector is equipped with audible and visual alarms, suitable for 24-hour on-line monitoring and real-time display of data on a bright display, suitable for fixed installation, small size and easy to carry.

    Specification

    Model GD300-N2
    Detection Principle Electrochemistry
    Gas Nitrogen (N2)
    Note* 1. It is recommended that this N2 gas detector only detects a single Nitrogen environment or only N2 and O2 in the environment, as well as Nitrogen leakage in normal air. If you are monitoring other gases mixed with N2, please contact us before purchasing.
    2. Nitrogen detectors cannot do zero point calibration in air, only do target calibration (the target concentration is the standard concentration value in clean air).
    Range 0-99.99% VOL, 0-100% VOL
    Resolution 0.01%VOL (0-99.99%VOL), 0.1%VOL (0-100%VOL)
    Calibration Kit Gas pressure regulator (calibration gas cylinder NOT included)
    Accuracy ≤±3% F.S.
    Responce Time ≤10s
    Repeatability ≤±1%
    Recovery Time ≤10s
    Linearity Error ≤±1%
    Zero Shift ≤±1% (F.S./year)
    Signal Output (Optional) Note 4-20mA and RS485
    Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
    Alarms Sound, light
    Display High light nixie tube display
    Installation Wall-mounted, piping type, flow-type (according to the detected environment)
    Connection Power connection type: G1/2 male thread explosion-proof flexible pipe
    Pipe-mounted type: M45*P2.0
    Operating Time 24h
    Explosion-proof Grade II 2G Ex db IIC T4 Gb
    Protection Grade IP65
    Certification CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
    Working Voltage 12~36V DC
    Case Material Die-casting aluminum housing
    Operating Temperature -20℃~50℃
    Operating Humidity 0~95%RH (non-condensing)
    Dimension 206*179*90mm
    Weight ≤1.6kg
    Power Adapter Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)


    Fixed Gas Monitor User Manual

    Gas Tester Functions

    • This hydrogen gas detector adopts three-wire 4-20mA analog signal output, relay output, RS485 output (optional).
    • The original imported sensors, with a unique infrared remote control function, non-contact operation and maintenance of hydrogen gas tester.
    • Compatible with a variety of control alarms, PLC, DCS and other control systems, you can realize remote monitoring, gas monitoring is more accurate and reliable.
    • Explosion-proof design, fast, credible and more stable.
    • Full software auto-calibration function with temperature compensation can perfectly realize the compensation of gas concentration under different temperature environment.

    Fixed N2 Gas Tester Details

     Fixed gas monitor details

    Fixed Nitrogen Gas Tester with Alarm Dimension (Unit: mm)

    Fixed gas monitor with alarm dimension

    Tips: Is the installation process of this nitrogen detector complicated?

    The installation process is relatively simple, but should be completed by a qualified technician. Stationary nitrogen detectors usually need to be connected to a power supply and communication system and calibrated for the specific installation environment. Typically, the installation location should be in an area where nitrogen leaks are likely to be present and to ensure that the detector is able to cover the required detection range. A detailed installation guide is supplied with the gas detector to ensure correct wiring and mounting position so that the unit can optimally perform the monitoring task.